![ABB UNO-DM-1.2-TL-PLUS Manual Download Page 98](http://html.mh-extra.com/html/abb/uno-dm-1-2-tl-plus/uno-dm-1-2-tl-plus_manual_3045417098.webp)
- 98 -
000696DG
7 - Operation
C
ommissioning (Via web user interface)
Do not place objects of any kind on the inverter during operation! Do not touch the heat sink
while the inverter is operating! Some parts may be very hot and could cause burns.
Before proceeding with commissioning, make sure you have carried out all the checks and
verifications indicated in the section on preliminary checks.
Commissioning is carried out via wireless connection to the inverter’s
internal web user interface. Initial setup of the system must therefore be
carried out via a tablet, notebook or smartphone with a wireless connec-
tion.
• Close the DC disconnect switch to supply the inverter with input voltage
from the photovoltaic generator.
Make sure irradiation is stable and adequate for the inverter commissioning procedure to be
completed.
Pre-commissionig phase 1 - Connection to the local Wi-Fi network
DEVICE USED TABLET/SMARTPHONE:
• Once the inverter is powered, launch a QR reader for mobile and SCAN
the QR code
C
marked with
symbol content on the “Wireless
Identification Label” (placed on the side of the inverter or applied during
the commissioning phase to the quick installation guide on cover page)
• Connect to inverter network (tap connect).
The name of the wireless network created by the system that the con-
nection should be established with, will be:
ABB-XX-XX-XX-XX-XX-XX
where “
X
” is a hex digit of the wireless MAC address
A
(MAC address
can be found on the “Wireless Identification Label” placed on the side
of the inverter or applied during the commissioning phase to the quick
installation guide on cover page).
• After this step wait 10 seconds to allow the WLAN connection
DEVICE USED LAPTOP:
• Enable the wireless connection on the laptop which is being used for the
board setup and connect it to the Access Point created by the inverter sy-
stem: the name of the wireless network created by the system that the
connection should be established with, will be:
ABB-XX-XX-XX-XX-XX-XX
where “
X
” is a hex digit of the wireless MAC address
A
(MAC address
can be found on the “Wireless Identification Label” placed on the side
of the inverter or applied during the commissioning phase to the quick
installation guide on cover page).
• When prompted, type the “product key”
B
(including the dashes.
Example: 1234-1234-1234-1234) as the network password to access
the inverter’s access point. The product key is printed on the “Wireless
Identification Label” placed on the side of the inverter or applied during
the commissioning phase to the quick installation guide on cover page.
SN WLAN: SSSSSSSSSS
PN WLAN: PPP.PPPPP.PP
MAC: XX:XX:XX:XX:XX:XX
SN Inverter: SSSSSSSSSS
MAC: XX:XX:XX:XX:XX:XX
PK: KKKK-KKKK-KKKK-KKKK
Remove and apply
on the Quick
installation guid
e
A
C
B
A