![ABB UNO-DM-1.2-TL-PLUS Manual Download Page 151](http://html.mh-extra.com/html/abb/uno-dm-1-2-tl-plus/uno-dm-1-2-tl-plus_manual_3045417151.webp)
- 151 -
000699BG
7 - Operation
• Crepuscolar (display text “Crepuscolar”)
The relay is activated (status: switched) as soon as the inverter input
voltage exceeds the activation voltage set.
The relay switch to rest position when the input voltage drops below 70%
of the activation voltage set.
This mode is useful for disconnecting any output transformers that could
have unnecessary consumption during the night.
• Alarm Latch (display text “Alarm Latch”)
The relay is activated (status: switched) whenever an error (code Exxx)
or a warning (code Wxxx) is present (see the table below). When the in-
verter returns to the normal operating state and reconnects with the grid,
the contact returns to its position of rest.
Alarms for which the relay is activated
E001
E002
E003
E004
E005
E006
E007
E010
E011
E012
E013
E014
E015
E016
E017
E018
E019
E020
E021
E022
E023
E025
E026
E027
E028
E029
E030
E031
E032
E033
E034
E035
E036
E037
E046
E050
E051
E053
E054
E055
E056
E057
E058
E065
E066
E067
E068
E069
E070
E074
E077
E078
E080
E084
E086
E087
E088
E089
W002
W003
W004
W005
W006
W007
W009
W011
W015
W017
W018
W019
W021
W022
W023
W024
W027
W029
W030
W036
W037
W039
W040
W042
W043
W046
W047
W048
W051
W058
W059
If the alarm condition is persistent, the relay will remain activated
(status:switched)
Vin > Vstart
Vin < Vstart
GRID RECONNECTION
t=based on Country Standard
Vin
IS STILL LESS THAN
Vstart
Yes
No
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
Relay State:
Idle
Relay State: Switched
Relay State:
Idle
INVERTER RUN
ERROR OCCURENCY
ERROR MESSAGE
t=15s
GRID RECONNECTION
t=based on Country Standard
ERROR
STILL
PRESENT
Yes
No
N.C.
N.O.
N.C.
N.O.
Relay State:
Idle
Relay State: Switched
N.C.
N.O.
Relay State: Switched