39
6
SPARES LIST
6.1
Consumables
The following spares are required at regular intervals:
Item
Part No.
Roll Chart – 25m
30 division ....................................................... PR100–9000R
40 divisions ..................................................... PR100–9001R
50 divisions ..................................................... PR100–9002R
60 divisions ..................................................... PR100–9003R
70 divisions ..................................................... PR100–9004R
75 divisions ..................................................... PR100–9005R
Fanfold Chart – 12m
30 division ....................................................... PR100–9000F
40 divisions ..................................................... PR100–9001F
50 divisions ..................................................... PR100–9002F
60 divisions ..................................................... PR100–9003F
70 divisions ..................................................... PR100–9004F
75 divisions ..................................................... PR100–9005F
Pen capsule
Up to three traces ........................................... PR100–0210
Up to three traces (high temperature
) ...... PR100–0229
Four to six traces ............................................ PR100–0211
Four to six traces (high temperature
) ....... PR100–0230
Note.
The
high temperature cartridge
is designed for use in
recorders operating at ambient temperatures consistently
above 30
°
C.
6.2
Replacement Parts
The following spares are replacement items:
Item
Part No.
Roll chart cassette .......................................... SR100–0054
Fanfold chart cassette .................................... SR100–0055
Analog Input module
Standard:
3 input pack ....................................... SR100–0517
6 input pack ....................................... SR100–0514
Relay output module ....................................... PR100–0545
Processor board ............................................. SR100–0505
Motherboard ................................................... SR100–0195
Power Supply:
115 to 230V A.C. ...................................... PR100–0445
10 to 30V D.C. ......................................... PR100–0495
10 to 30V A.C. .......................................... PR100–0496
5.1
Arc Suppression Capacitors – Fig. 5.1
Arc suppression capacitors are fitted across the contacts of
the alarm/control relays. If these contacts are used to operate
external relays, the capacitor leakage current may be
sufficient to prevent the external relay from de-energizing. If
so, switch off the power supply and external alarm circuits.
Identify the appropriate relay module and remove it
– see Fig. 5.1
Unsolder and remove the appropriate capacitors, shown in
Fig. 5.1 and refit the module.
IC2
IC3
IC4
IC5
IC6
IC7
Relay 1
Relay 2
Relay 3
NC
NO
NC
NO
NC
NO
Relay Output Module – Type R
Arc Suppresion Capacitors
…5
SIMPLE FAULT FINDING
Fig. 5.1 Location of Arc Suppression Capacitors