![background image](http://html.mh-extra.com/html/abb/sace-emax-2/sace-emax-2_installation-operation-and-maintenance-instructions_2172039.webp)
ABB | SACE Emax 2
Ekip Dip protection release | 1 - Operator interface
35 | © 2013
ABB |
1SDH001000R0002 - L7804
Ekip Dip protection release
1 - Operator interface
Introduction
The operator interface of the Ekip Dip protection release allows you to:
• Set the parameters relating to the available protections.
• View the status of the release and alarms.
• Connect to the frontal connector to communicate and perform the tripping test.
Components of the interface
The Ekip Dip operator interface appears as follows:
Figure 63
The following table provides a description of the components of the interface:
Position
Type
Description
A
LED
Protection LED L (alarm and trip)
B
Protection LED L (prealarm)
C
Protection LED S (alarm and trip)
D
Protection LED I (trip)
E
Protection LED G (alarm and trip)
F
Power LED (release powered and on)
G
Protections:
thresholds
Protection L dip-switch (threshold I1)
H
Protection S dip-switch (threshold I2)
I
Protection I dip-switch (threshold I3)
L
Protection G dip-switch (threshold I4)
M
Protections: times
Protection L dip-switch (time t1)
N
Protection S dip-switch (time t2 and type of curve)
Or
Protection G dip-switch (time t4 and type of curve)
P
Settings
Neutral and Frequency dip-switch
Q
Test
Test pushbutton
R
Test connector
IMPORTANT: The figure above refers to a an Ekip Dip, LSIG version. In the
case of Ekip Dip versions LI or LSI, LEDs and dip-switches related to the
protections present are available.