3.11.2
Functions
CONDITION MONITORING
AND SUPERVISION
OR
AND
CONTROL AND INDICATION
1)
MEASUREMENT
FEEDER PROTECTION AND CONTROL RELAY
STANDARD
CONFIGURATION
PROTECTION
LOCAL HMI
Object
Ctrl
2)
Ind
3)
CB
DC
ES
1)
Check availability of binary inputs/outputs
from technical documentation
2)
Control and indication function for
primary object
3)
Status indication function for
primary object
R
L
Clear
ESC
I
O
Configuration
A
System
HMI
Time
Authorization
R
L
Clear
ESC
I
O
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr
IL2 0 A
A
REMARKS
Optional
function
No. of
instances
Alternative
function to be
defined when
or
dering
OR
Io/Uo
Calculated
value
3×
REF615
COMMUNICATION
Protocols:
IEC 61850-8-1/-9-2LE
Modbus
®
IEC 60870-5-103
DNP3
Interfaces:
Ethernet: TX (RJ45), FX (LC)
Serial:
Serial glass fiber (ST),
RS-485, RS-232
Redundant protocols:
HSR
PRP
RSTP
J
- I, U, Io, Uo, P, Q, E, pf, f
- Limit value supervision
- Load pr
ofile
record
- RTD/mA measurement (optional)
- Symmetrical components
4
5
Analog interface types
1)
Current transformer
V
oltage transformer
1)
Conventional transformer inputs
ALSO AVAILABLE
- Disturbance and fault recorders
- Event log and
recorded data
- High-Speed Output module (optional)
- Local/Remote push button on LHMI
- Self-supervision
- Time synchronization: IEEE 1588 v2,
SNTP, IRIG-B
- User management
- Web HMI
1
-
2
3
1
2
SYNC
25
O
→
I
79
2×
I2>
46
3Ith>F
49F
3I>>>
50P/51P
3×
ARC
50L/50NL
Master Trip
Lockout relay
94/86
2×
Io>
→
67N-1
Io>>
→
67N-2
Io>IEF
→
67NIEF
3×
Yo>
→
21YN
3×
Po>
→
32N
Io>HA
51NHA
3×
3U<
27
U2>
47O-
U1<
47U+
3×
3U>
59
3×
Uo>
59G
3×
f>/f<,
df/dt
81
2×
3I>
→
67-1
3I>>
→
67-2
3I>/Io>BF
51BF/51NBF
3I2f>
68
PQM3I
PQM3I
PQM3U
PQM3V
PQMU
PQMV
OR
OR
I2/I1>
46PD
18×
MAP
MAP
Io>>
51N-2
2xRTD
1xmA
MCS 3I
MCS 3I
FUSEF
60
CBCM
CBCM
2×
TCS
TCM
OPTS
OPTM
3I
U
L1
U
L2
U
L3
U
12
U
12
Uo
Io
Io
U
L1
U
L2
U
L3
Uo
3I
Io
U
L1
U
L2
U
L3
PQUUB
PQVUB
3×
U
L1
U
L2
U
L3
SOTF
SOTF
Master Trip
Lockout relay
94/86
3×
2×
GUID-8736C89A-53BA-49B3-95A1-3984B605504F V2 EN
Figure 385:
Functionality overview for standard configuration J
3.11.2.1
Default I/O connections
Connector pins for each input and output are presented in the IED physical
connections section.
1MRS756378 S
Section 3
REF615 standard configurations
REF615
257
Application Manual