DARREC1
INIT_1
INIT_2
INIT_3
INIT_4
INIT_5
INIT_6
DEL_INIT_2
DEL_INIT_3
DEL_INIT_4
BLK_RECL_T
BLK_RCLM_T
BLK_THERM
CB_POS
CB_READY
INC_SHOTP
INHIBIT_RECL
RECL_ON
SYNC
OPEN_CB
CLOSE_CB
CMD_WAIT
INPRO
LOCKED
PROT_CRD
UNSUC_RECL
AR_ON
READY
ACTIVE
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR
B1
B2
O
X120_BI3_CB_OPENED
DARREC1_OPEN_CB
DARREC1_CLOSE_CB
PHIPTOC1_OPERATE
PHHPTOC1_OPERATE
NSPTOC1_OPERATE
PHHPTOC2_OPERATE
NSPTOC2_OPERATE
EFLPTOC1_OPERATE
EFHPTOC1_OPERATE
PDNSPTOC1_OPERATE
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
CBXCBR1_SELECTED
DARREC1_INPRO
DARREC1_UNSUC_RECL
GUID-4DA43380-6D91-47AE-BB5C-56BCE03BEA4B V1 EN
Figure 107:
Autoreclosing
General start and operate from all the functions are connected to minimum pulse timer
TPGAPC for setting the minimum pulse length for the outputs. The output from
TPGAPC is connected to the binary outputs.
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
OR6
B1
B2
B3
B4
B5
B6
O
TPGAPC1
IN1
IN2
OUT1
OUT2
GENERAL_START
GENERAL_OPERATE
PHIPTOC1_OPERATE
PHLPTOC1_OPERATE
PHHPTOC1_OPERATE
NSPTOC1_OPERATE
PHHPTOC2_OPERATE
NSPTOC2_OPERATE
EFLPTOC1_OPERATE
EFHPTOC1_OPERATE
EFIPTOC1_OPERATE
EFLPTOC2_OPERATE
PDNSPTOC1_OPERATE
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
PHLPTOC1_START
PHHPTOC1_START
PHHPTOC2_START
PHIPTOC1_START
NSPTOC1_START
NSPTOC2_START
EFLPTOC1_START
EFLPTOC2_START
EFIPTOC1_START
EFHPTOC1_START
PDNSPTOC1_START
GUID-ED986761-5FC9-4F1B-8D27-8B3AF824133F V1 EN
Figure 108:
General start and operate signals
The operate signals from the protection functions are connected to the two trip logics
TRPPTRC1 and TRPPTRC2. The output of these trip logic functions is available at
binary output X100:PO3 and X100:PO4. The trip logic functions are provided with
lockout and latching function, event generation and the trip signal duration setting. If
the lockout operation mode is selected, the binary input X120:BI4 has been assigned
to
RST_LKOUT
input of both the trip logic to enable external reset with a push button.
Section 3
1MRS756378 S
REF615 standard configurations
106
REF615
Application Manual