signal designation within the IED enables this configuration to be further adapted to
different primary circuit layouts and the related functionality needs by modifying the
internal functionality using PCM600.
3.6.2
Functions
CONDITION MONITORING
AND SUPERVISION
OR
AND
CONTROL AND INDICATION
1)
MEASUREMENT
FEEDER PROTECTION AND CONTROL RELAY
STANDARD
CONFIGURATION
PROTECTION
LOCAL HMI
Object
Ctrl
2)
Ind
3)
CB
DC
ES
1)
Check availability of binary inputs/outputs
from technical documentation
2)
Control and indication function for
primary object
3)
Status indication function for
primary object
R
L
Clear
ESC
I
O
Configuration
A
System
HMI
Time
Authorization
R
L
Clear
ESC
I
O
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr
IL2 0 A
A
REMARKS
Optional
function
No. of
instances
Alternative
function to be
defined when
or
dering
OR
Io/Uo
Calculated
value
3×
COMMUNICATION
Protocols:
IEC 61850-8-1
Modbus
®
IEC 60870-5-103
DNP3
Interfaces:
Ethernet: TX (RJ45), FX (LC)
Serial:
Serial glass fiber (ST),
RS-485, RS-232
Redundant protocols:
HSR
PRP
RSTP
REF615
D
- I, Io
- Limit value supervision
- Load pr
ofile
record
- RTD/mA measurement (optional)
- Symmetrical components
4
-
Analog interface types
1)
Current transformer
V
oltage transformer
1)
Conventional transformer inputs
OPTS
OPTM
2×
TCS
TCM
O
→
I
79
2×
I2>
46
I2/I1>
46PD
3Ith>F
49F
3I>>>
50P/51P
3×
ARC
50L/50NL
Io>>
51N-2
3I>
51P-1
3I>/Io>BF
51BF/51NBF
3I2f>
68
2×
3I>>
51P-2
CBCM
CBCM
Io>>>
50N/51N
2×
Io>
51N-1
Io>HA
51NHA
2×
Master Trip
Lockout relay
94/86
18×
MAP
MAP
3I
Io
3×
1
-
2
3
1
2
ALSO AVAILABLE
- Disturbance and fault recorders
- Event log and
recorded data
- High-Speed Output module (optional)
- Local/Remote push button on LHMI
- Self-supervision
- Time synchronization: IEEE 1588 v2,
SNTP, IRIG-B
- User management
- Web HMI
SOTF
SOTF
GUID-2907E142-1D1E-4109-9603-76FDF7A15F02 V2 EN
Figure 127:
Functionality overview for standard configuration D
3.6.2.1
Default I/O connections
Connector pins for each input and output are presented in the IED physical
connections section.
1MRS756378 S
Section 3
REF615 standard configurations
REF615
115
Application Manual
Summary of Contents for relion REF615