Tension Electronics PFEA113, User Manual
Section 3.8.1 Performing Fast Setup using Hanging Weights
3BSE029382R0101 Rev C
3-7
NOTE
When using
HangWeight
the
wrap
gain value is calculated by the tension
electronics.
To
be able to read the wrap gain value, go to menu
EnterWrapGain
of the desired
roll.
9
Select the load cells (2, SingleSideA or SingleSideB) that
support the roll from the list
with
or .
Confirm
with
.
10
Check the nominal load on the load cell name plate.
Select nominal load from the list with
or
.
Confirm with
.
11
1.
Apply a known weight on the roll (see
2.
Enter the value of the known weight. Confirm with
.
12
Select
Voltage
or
Current
from the list with
or
.
Confirm with
.
13
Voltage
selected:
Enter the tension value corresponding to 10 V.
or
Current
selected:
Enter the tension value corresponding to 20 mA.
Confirm with
.
14
Select filter setting (5, 15, 30, 75, 250, 750 or 1500 ms) from
the list with
or
. Confirm with
.
15
FastSetUp
of a system with one roll is now completed.
Press
to finish the fast setup and go to the operator
menu.
Proceed with the FastSetUp for Roll 2. In step 4, select the
load cells (2, SingleSideC or SingleSideD) that support
Roll 2 from the list with
or
. Confirm with
.
CellsOnRoll 1
[2]
NominalLoad
[1 kN 225 lbs]
HangWeight
[XXXXXX] N
AnalogOut 1
[ZZ]
SetTensionAt10V
[XXXXXX] N
SetTensionAt20mA
[XXXXXX] N
FilterSettings
[250 ms 1.5Hz]
Finished
PressOk
To
Operator
Menu
Summary of Contents for PFEA 113
Page 32: ...Tension Electronics PFEA113 User Manual Chapter 2 Installation 2 16 3BSE029382R0101 Rev C ...
Page 92: ...Tension Electronics PFEA113 User Manual Chapter 5 Maintenance 5 2 3BSE029382R0101 Rev C ...
Page 104: ...Tension Electronics PFEA113 User Manual Chapter 6 Fault tracing 6 12 3BSE029382R0101 Rev C ...
Page 259: ......