Tension Electronics PFEA113, User Manual
Appendix G PFTL 201 - Designing the Load Cell Installation
G-12
3BSE029382R0101 Rev C
Mechanical data
Length
C/CE
450
(17.7)
450
(17.7)
450
(17.7)
mm
(inch)
D/DE
650
(25.6)
650
(25.6)
Width
C
110
(4.3)
110
(4.3)
110
(4.3)
mm
(inch)
D
150
(5.9)
150
(5.9)
CE
180
(7.1)
180
(7.1)
180
(7.1)
DE
220
(8.7)
220
(8.7)
Height
C/CE
125
(4.9)
125
(4.9)
125
(4.9)
mm
(inch)
D/DE
150
(5.9)
150
(5.9)
Weight
C/CE
35
(77)
35
(77)
35
(77)
kg
(lbs)
D/DE
80
(176)
80
(176)
Material
C/D/CE/DE
Stainless steel SIS 2387
DIN X4CrNiMo165
Accuracy
Accuracy class
C/D/CE/DE
± 0.5
%
Linearity deviation
± 0.3
Repeatability error
< ± 0.05
Hysteresis
<0.2
Compensated temperature range
+20 - +80 (+68 - +176)
C (
F )
Zero point drift
50 (28)
ppm/K
(ppm/
F)
Sensitivity drift
100 (56)
Working temperature range
-10 - +90 (+14 - +194)
C (
F )
Zero point drift
100 (56)
ppm/K
(ppm/
F)
Sensitivity drift
200 (111)
Storage temperature range
-40 - +90 (-40 - +194)
C (
F )
Table G-3. Technical data for different types of load cell PFTL 201
PFTL 201,
type
Data
Unit