Table A-13. Factory Default Settings
Name
PFEA113
Display language
English
Display unit
N
Load cell combination
Two rolls
Gain scheduling
No
Roll 1
•
Object type
Standard roll
•
Load cell nominal load
1.0 kN 225 lbs
•
Wrap gain
1
Roll 2
•
Object type
Standard roll
•
Load cell nominal load
1.0 kN 225 lbs
•
Wrap gain
1
AO1
•
Function
Current
•
Connect signals
A+B
•
Filter settings
250 ms
•
High tension
2000 N
•
High output
20.00 mA
•
Low tension
0 N
•
Low output
4.00 mA
•
High limit
21.00 mA
•
Low limit
0.00 mA
AO2
•
Function
Current
•
Connect signals
C+D
•
Filter settings
250 ms
•
High tension
2000 N
•
High output
20.00 mA
•
Low tension
0 N
•
Low output
4.00 mA
•
High limit
21.00 mA
•
Low limit
0.00 mA