Tension Electronics PFEA113, User Manual
Section G.7.3 Mounting
3BSE029382R0101 Rev C
G-9
* Strength class 12.9 must be used for load cells PFTL 201C-50 kN and PFTL 201D-100 kN.
Figure G-3. Typical installation
Table G-1. MoS
2
lubricated , galvanized screws according to ISO 898/1
Strength class
Dimension
Tightening torque
8.8 * (12.9)
M24
572 (963) Nm
8.8 * (12.9)
M36
1960 (3310) Nm
Table G-2. Waxed screws of stainless steel according to ISO 3506
Strength class
Dimension
Tightening torque
A2-80 *
M24
629 Nm
A2-80 *
M36
2160 Nm
Pressductor
System
Upper adapter plate
with stop blocks
Lower adapter plate
with stop blocks
Roll
Bearing housing
Load cell
Foundation