Tension Electronics PFEA113, User Manual
Appendix F PFCL 201 - Designing the Load Cell Installation
F-12
3BSE029382R0101 Rev C
Figure F-6. Building Height
Accuracy
Accuracy class
C/CD/CE
± 0.5
%
Linearity deviation
< ± 0.3
Repeatability error
< ± 0.05
Hysteresis
< 0.2
Compensated temperature range
+20 - +80
(+68 - +176)
C
F)
Zero point drift
50
(28)
ppm/K
(ppm/
F)
Sensitivity drift
100
(56)
Working temperature range
–10 - +90
(+14 - +194)
C
F)
Zero point drift
100
(56)
ppm/K
(ppm/
F)
Sensitivity drift
200
(111)
Storage temperature range
–40 - +90
(–40 - +194)
C
F)
Table F-3. Technical Data
Type
PFCL 201
Unit
Pressductor
System
h
h
1) Definitions of direction designations “
V
”and “
A
” in
F
V
and F
A
are given in
.
2) F
max
and F
Vmax
are allowed at the same time.
3) Max. permitted load for the load cell is 10 × F
nom
.
The overload capacity for the total installation may
be limited by the screws.