Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning
3-6
3BSE029382R0101 Rev C
3.8.1 Performing Fast Setup using Hanging Weights
The simplest method to set the wrap gain in this tension system is to use a known weight that
loads the center of the roll with a rope that follows the web path exactly.
Figure 3-1. Setting Wrap Gain with Hanging Weights (example of installation)
Follow the steps below to run a fast setup using hanging weights.
1
Press
for 5 seconds to go to the
FastSetUp
menu.
2
Press
to start the fast setup sequence.
3
Select web width if the unit is set to N/m, kN/m, kg/m or pli.
The same width is applied to Roll 1 and Roll 2.
4
Select number of rolls (1 or 2)
5
Select roll (1 or 2).
The menu is hidden if NumberOfRolls is set to [1].
6
Zero set is used to compensate for load cell zero signal and
tare weight.
Zero set must be done with no tension applied to the roll.
7
1.
Check that no load is applied on the roll.
2.
Press
to zero set. “
ActionDone
” is shown on the
display for one second to confirm the zero setting action.
8
Select
HangingWeights
from the list with
and
.
Confirm with
.
Load cell
Weight
Rope
supported roll
All rolls must be
free turning idlers.
To keep friction
losses low, only
use the closest
rolls to define web
path.
WebTension
> 5
seconds
FastSetUp
SetWebWidth
XXXXXX
NumberOfRolls
[2]
Roll 1 or 2
[1]
ZeroSet A, B
[ZZ]
WithNoTension
PressOkToZeroSet
SetWrapGain
[HangingWeights]
Summary of Contents for PFEA 113
Page 32: ...Tension Electronics PFEA113 User Manual Chapter 2 Installation 2 16 3BSE029382R0101 Rev C ...
Page 92: ...Tension Electronics PFEA113 User Manual Chapter 5 Maintenance 5 2 3BSE029382R0101 Rev C ...
Page 104: ...Tension Electronics PFEA113 User Manual Chapter 6 Fault tracing 6 12 3BSE029382R0101 Rev C ...
Page 259: ......