![ABB J2007003L301A Quick Start Manual Download Page 10](http://html.mh-extra.com/html/abb/j2007003l301a/j2007003l301a_quick-start-manual_2837989010.webp)
Page 10
© 2021 ABB. All rights reserved.
Version 1.0
Information
-
Tools Required
•
Wire cutters and strippers
•
Digital meter with an accuracy of ±0.02%
•
Torque wrench–
0
-
65
in
-
lb (0
-
10 Nm)
•
Sockets
5/16”, 7/16”.
•
Cable Crimpers
•
Screw drivers (flat
-
blade and Phillips #1 and #2)
Step 1 –
Mount Shelf
1.
Position the SPS shelf System mounting ears with the
mounting frame.
2.
Attach shelf to the frame using three screws on each
side (four on each side)
-
12
-
24 (provided).
3.
Torque to 35 in
-
lb (4Nm)
-
5/16”
socket.
4.
Provide 2 inch minimum clearance at back of shelf for
converter airflow.
Step 2 –
Connect Chassis Ground
1.
Lug Landings: #10 double
-
hole on 5/8
-
inch center (lugs not provided)
2.
Minimum 10 AWG wire is recommended.
3.
Torque to 30 in
-
lb (3.4Nm)
-
5/16”
socket.
Some applications may rely on frame mounting screws for shelf ground omitting the chassis ground cable.
Mounting Ears
Chassis Ground Connection
Figure 4: Mounting Shelf
Figure 5: Chassis Ground Connection
QUICK START GUIDE