Illustration, cabling inside upper arm housing
The figure below shows how the cabling is run inside the upper arm housing.
xx0400001250
Signal cabling; connectors for motors on axes 3, 4, 5 and 6: R3.FB3, R3.FB4,
R3.FB5 and R3.FB6
A
Power cabling; connectors for motors on axes 3, 4, 5 and 6: R3.MP3, R3.MP4,
R3.MP5 and R3.MP6
B
Optional connector: R2.CP
C
Optional connector: R2.CS
D
Distance console with contact panel
E
Cable clamp unit
F
Attachment screws, cable clamp unit (2 pcs, only one shown)
G
Clamp, signal cabling
H
Clamp, motor cabling
I
Connector plate
J
Connector holder
K
Cable tie, connector holder
L
Continues on next page
166
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.3.1 Replacing the cable harness, IRB 1600