2.4.2 Connecting power and the FlexPendant
Overview
The following illustration shows the connectors on the right side of the controller.
xx1500000503
Power switch
Q1
FlexPendant
XS4
Power input
XP0
Main AC power connector, IEC 60320-1 C14, 100-240 VAC, 50-60 Hz
Connecting power supply
Line fusing
Line fusing of the IRB 14000 is 5A at 100-240 V.
Rated power
Rated power of the IRB 14000 is 360 W.
Required equipment
Note
Equipment
Power supply cable (single phase)
8A
External circuit breaker
30mA
External earth fault protection at control cables 3 -15m
300mA
External earth fault protection at control cables >15m
See
Circuit diagram - IRB 14000
.