![ABB IRB 14000 Product Manual Download Page 139](http://html.mh-extra.com/html/abb/irb-14000/irb-14000_product-manual_5024139.webp)
Note
Action
Screw: 3HAB3409-233. (2 pcs)
Refit the cable bracket to the arm with the
screws.
3
Tightening torque: 0.8 Nm.
xx1400002607
Connecting the arm cabling to the controller
Note
Action
Connect the power and signal connectors
to the controller.
1
Left side:
•
A52.XS11,12,17,13,14,15,16
•
A52.X3
•
A52.SMB.X2,X4,X5
•
A33.X3
•
A2.XSEN
•
A2.XPCP
Right side:
•
A51.XS11,12,17,13,14,15,16
•
A51.X3
•
A51.SMB.X2,X4,X5
•
A33.X2
•
A1.XSEN
•
A1.XPCP
Connect the air hoses to the controller.
2
Secure the cabling again with cable ties.
3
Gently push the controller into the robot
body completely.
CAUTION
Be careful not to squeeze or damage the
cables and air hoses in any way.
4
Continues on next page
Product manual - IRB 14000
139
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.3.1 Replacing the complete arm
Continued