2.4.6 Connecting safety signals
Introduction
The IRB 14000 safety stop signals (SS) are accessed through the safety connector
on the interface on the left side panel of the controller. This is covered by a safety
bridge connector by default in standalone mode. If the bridge connector is removed,
it is external device mode.
xx1400002129
Safety signals
XS9
Standalone safety
IRB 14000 standalone is not connected to any external safety devices. The safety
connector on the foot interface is plugged with a safety bridge connector, that
closes both emergency stop channels of the FlexPendant.
The safety stop input on each drive monitors this channel, and triggers a safety
stop if the circuit is open or not powered.
4
XS/XP4
5
6
3
XS/XP9
1
2
3
4
5
6
7
8
(+)
(-)
(+)
(-)
24V
0V
DSQC462 Drive board_Right arm (1#)
-A51
DSQC462 Drive board_Left arm (2#)
-A52
FlexPendant
IRC5 controller
xx1500000013
Continues on next page
102
Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
2 Installation and commissioning
2.4.6 Connecting safety signals
Summary of Contents for IRB 14000
Page 1: ...Product manual IRB 14000 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 416: ...This page is intentionally left blank ...
Page 436: ...This page is intentionally left blank ...
Page 440: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......