![ABB IRB 14000 Product Manual Download Page 355](http://html.mh-extra.com/html/abb/irb-14000/irb-14000_product-manual_5024355.webp)
Removing the right arm's drive board
Use this procedure to remove the drive board.
Pulling the controller out partially
Note
Action
DANGER
Turn off all:
•
electric power supply
•
air pressure supply
to the robot, before starting the repair work on the
robot.
1
Flange screw (10 pcs)
xx1500000525
Remove the body cover.
ELECTROSTATIC DISCHARGE (ESD)
The equipment is sensitive to ESD. Before hand-
ling the equipment please read the safety inform-
ation in the section
2
xx1500000303
xx1500000364
Remove the attachment screws that fasten the
controller to the body.
3
Put a trolley beneath the controller.
4
Continues on next page
Product manual - IRB 14000
355
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.9 Replacing the right arm's drive board
Continued