![ABB IRB 14000 Product Manual Download Page 340](http://html.mh-extra.com/html/abb/irb-14000/irb-14000_product-manual_5024340.webp)
Note
Action
xx1500000601
Disconnect the grounding cable.
5
xx1500000365
Carefully pull the controller partially out in the
rails.
CAUTION
The cabling is still connected inside the robot, so
be careful not to strain the cables!
6
Removing the axis computer
Note
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
WARNING - The unit is sensitive to ESD!
2
Disconnect the connectors:
•
A42.X4 (X4 Measurement link 1)
•
A42.X5 (X5 Measurement link 2)
3
Continues on next page
340
Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.7 Replacing the axis computer
Continued