![ABB IRB 14000 Product Manual Download Page 322](http://html.mh-extra.com/html/abb/irb-14000/irb-14000_product-manual_5024322.webp)
Removing the power supply
Use this procedure to remove the power supply.
Preparations before removing the power supply
Note
Action
DANGER
Turn off all:
•
electric power supply
•
air pressure supply
to the robot, before starting the repair work on the
robot.
1
xx1500000370
Check if there is enough space beneath the robot
to remove the bottom cover. If not:
•
Place the robot in its calibration position.
•
Remove the fastening screws.
•
Put the robot on a flat and stable surface
in the following position:
2
Removing the power supply
Note
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
xx1500000268
Remove the bottom cover.
CAUTION
Be careful not to damage the cables.
2
xx1500000286
Remove the plastic covers on the connectors on
the side of the power supply.
3
Continues on next page
322
Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.4 Replacing the power supply
Continued
Summary of Contents for IRB 14000