Procedure
1. Install the cover plate (B) on the
foundation (A).
2. Install the fasteners (C).
3. Tighten the fasteners to the correct
torque. For the specification, refer to
section
6.3
Mechanical installation of the charge post
6.3.1
Install the charge post - general procedure
Preliminary requirements
1.
The charge post is above the foundation.
Warning: Make sure that you secure the load when you do work below
the charge post. Obey all related local regulations.
Note: The manufacturer installed the cooling unit at the factory,
including the cooling liquid.
Procedure
1. Get access to the charge post:
a. Remove the plinth covers of the charge post. Refer to section
b. Open the door of the charge post. Refer to section
c. Remove the protection plate of the charge post. Refer to section
.
2. Remove the cable gland plates. Refer to section
3. Guide the cables through the cable glands. Apply the full cable slack. Refer to
section
.
4. Install the charge post on the foundation. Refer to section
.
5. Install the cable gland plates. Refer to section
6. Close the charge post:
a. Install the protection plate of the charge post.
b. Close and lock the door of the charge post.
c. Install the plinth covers of the charge post.
7. Replace the eye bolts on the charge post with the caps. Refer to section
.
A
C
B