12.15
Dimensions
12.15.1
Power cabinet
Parameter
Specification
[mm]
[in]
Width (X-dimension)
1170
46.1
Depth (Y-dimension)
770
30.3
Height (Z-dimension)
2030
30.3
Required cable slack for the AC input ca-
ble (measured from the top of the foun-
dation)
1000
39.4
Required cable slack for the PE cable
(measured from the top of the founda-
tion)
2000
78.7
Required cable slack for the DC output
cable (measured from the top of the
foundation)
2000
78.7
Required cable slack for the AC auxiliary
power cable (measured from the top of
the foundation)
2000
78.7
Required cable slack for the interlock
and DC guard, and CAN cables (meas-
ured from the top of the foundation)
2000
78.7
12.15.2
Charge post
Parameter
Specification
[mm]
[in]
Width of the charge post (X-dimension) 590
23.2
Depth of the charge post (Y-dimension) 425
16.7
Height of the charge post (Z-dimension) 2463
97.0
Required cable slack for the PE wire
(measured from the top of the founda-
tion)
700
27.6
Required cable slack for the DC power
cables (measured from the top of the
foundation)
700
27.6
Required cable slack for the AC auxiliary
power cable (measured from the top of
the foundation)
1200
47.2
Required cable slack for the interlock
and DC guard cable (measured from the
top of the foundation)
1200
47.2
Technical data
80
9AKK107992A6488-EN | 004