![ABB Focus II FII-4-14 Series Original Instructions Manual Download Page 9](http://html.mh-extra.com/html/abb/focus-ii-fii-4-14-series/focus-ii-fii-4-14-series_original-instructions-manual_4042009.webp)
9
www.abb.com/lowvoltage
2TLC172015M0201, rev. D
Code not necessary
Code B
Code A
3 Mechanical Installation
The location where the safety barrier is to be installed must fulfil the technical requirements. Prior to
installation, the ambient temperature, electromagnetic and/or optical interference, among other things,
should be taken into consideration.
3.1 Mechanical Assembly
The prof ile of the light curtain is assembled with the accompanying brackets, and mounting screws that
slide in the prof ile slots (see 17-19, 22). These make it easier to adjust the transmitter and receiver in level
with each other.
NB!
If several barriers are used, they must be mounted so that each transmitter does not interfere with the
receiver of a nearby barrier. Multiple barriers should be installed as below or could be used with coding, see
4.5 and 5.6.
The scan code feature of the Focus II system allows for placement of systems in close proximity and in line
with each other. The distinctive coding of the beams provide for unique operation of a system while in view
of another system with a different scan code. Two unique codes are available on the Focus II, see section
4.3 on how to set the codes.