![ABB Focus II FII-4-14 Series Original Instructions Manual Download Page 27](http://html.mh-extra.com/html/abb/focus-ii-fii-4-14-series/focus-ii-fii-4-14-series_original-instructions-manual_4042027.webp)
27
www.abb.com/lowvoltage
2TLC172015M0201, rev. D
5.8 Dimensional Drawing
L:
Total length of the Focus II system
F:
Protective height where an object equal or greater
to the resolution is detected.
E:
Detection zone
A:
Dead zone
L:
Total length of the Focus II system
I:
Beam distance
E:
Detection zone
A:
Dead zone
5.9 Label description
F
20
A
E
L
I
A
L
E
Model:
Type:
Range:
Resolution: (mm)
Prot. height: (mm)
Supply:
Response time: (See manual)
Power consumption:
Protection:
SW release:
Prod. date:
Serial no.:
Operating temp:
RoHS
Certified by:
TÜV
CSA
ABB AB
JOKAB SAFETY
Varlabergsvägen 11
434 39 Kungsbacka
SWEDEN
Jokab Safety
A
F
L
G
H
B
I
C
J
D
E
K
M
Bar code
A
Model type: e.g. FRII-4-14-600
FII
= Focus II re transmitter
FRII = Focus II receiver
FTII = Focus II transmitter
B
Power supply: 24 VDC
C
Power consumption: e.g. 5 W
D
Protection: IP65
E
Software release: e.g. 1.3.6
F
Type: 4
G
Resolution: e.g. 14 or 30 mm (21/28 or 45/60)
H
Protection height: e.g. 600 mm
I
Response time: e.g. 35 ms
J
Operating temperature: -10 / +55°C
K
Manufacturing date: e.g. 12021
L
Range: e.g. S 0.2-7m, L 7-14m
M
Serial number: e.g. 312010116