![ABB Focus II FII-4-14 Series Original Instructions Manual Download Page 18](http://html.mh-extra.com/html/abb/focus-ii-fii-4-14-series/focus-ii-fii-4-14-series_original-instructions-manual_4042018.webp)
18
2TLC172015M0201, rev. D
www.abb.com/lowvoltage
Default setting
Switch
Status
Function
8
OFF
Manual reset
Single break if SB/DB selected
ON
Automatic reset
Double break if SB/DB selected
7
OFF
Refer to Coding section for further information
ON
6
OFF
EDM function disabled
ON
EDM function enabled
5 + 4
1
4
5
Muting and special functions
OFF
OFF
Muting T with time limit, 0.2 s allowed drop
2
OFF
ON
Muting L with time limit, 0.2 s allowed drop
2
ON
OFF
Muting X without time limit
6
, 0.2 s allowed drop
2
ON
ON
Special function with switches 1, 2 and 3
Light curtain specific settings:
Muting maps when muting T, L or X
are selected on switches 4 and 5
3
Special functions selection when
switches 4 and 5 are both ON
4
3+2+1
1
2
3
OFF
OFF
OFF
Muting all beams
Blanking ± 1 beam with T muting
OFF
OFF
ON
Muting on module 1, 2, 3 and 4
Bl1/-0 beam with T muting
OFF
ON
OFF
Muting on module 1, 2 and 3
Blanking ± 0 beam with T muting
OFF
ON
ON
Muting on module 1 and 2
Blanking ± 1 beam with L muting
ON
OFF
OFF
Muting on module 1
Bl1/-0 beam with L muting
ON
OFF
ON
Muting on module 2
Blanking ± 0 beam with L muting
ON
ON
OFF
Muting on module 3
Pre-Reset mode
ON
ON
ON
Muting on module 4
Single break/double break, Switch 8
1
2
3
4
5
6
7
8
OFF
ON
1
2
3
4
5
6
7
8
OFF
ON
Switch no. 8 in ON position
4.4 Setting up of Internal Change-Over Switches Receiver
•
Disconnect the power supply to the unit and open the small lid in the bottom cap (with the M12 connec-
tor) so that the two change-over switches become visible.
•
The change-over switches may be adjusted to the desirable position with a small, suitable screwdriver.
NB!
Make sure to always set switches in both banks to the same position (except switch 7 on the
receiver).