S
RO
= (K × T) + C
RO
(
K
and
T
according to a).
C
RO
= Intrusion distance to the hazard zone when reaching over prior to the actuation of the
light curtain/grid. Values are given in the table below.
___________________________________________________
1)
The text is reproduced from ISO 13855:2010 with permission from SIS Förlag AB, www.sis.se where also the
complete standard is available for purchase.
Height of upper edge of the detection zone of the electro-sensitive protective equipment
1
Height of
hazard zone
900
1000
1100
1200
1300
1400
1600
1800
2000
2200
2400
2600
Additional distance to hazard zone
C
RO
2600
a
0
0
0
0
0
0
0
0
0
0
0
0
2500
400
400
350
300
300
300
300
300
250
150
100
0
2400
550
550
550
500
450
450
400
400
300
250
100
0
2200
800
750
750
700
650
650
600
550
400
250
0
0
2000
950
950
850
850
800
750
700
550
400
0
0
0
1800
1100
1100
950
950
850
800
750
550
0
0
0
0
1600
1150
1150
1100
1000
900
850
750
450
0
0
0
0
1400
1200
1200
1100
1000
900
850
650
0
0
0
0
0
1200
1200
1200
1100
1000
850
800
0
0
0
0
0
0
1000
1200
1150
1050
950
750
700
0
0
0
0
0
0
800
1150
1050
950
800
500
450
0
0
0
0
0
0
600
1050
950
750
550
0
0
0
0
0
0
0
0
400
900
700
0
0
0
0
0
0
0
0
0
0
200
600
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
When a value of zero is given, the calculation of the minimum distance, S, should be made in accordance with chapter
3.3 Calculation of Minimum Distance for Installation, calculation point a).
NB!
Electrosensitive protective equipment with a height of the:
–
upper edge of the detection zone below 900 mm is not included since they do not offer sufficient protection against
circumventing or stepping over
–
lower edge of the detection zone above 300 mm in relation to the reference plane does not offer sufficient protec
-
tion against crawling below.
a
Approach to the hazard zone by reaching over is impossible
NB!
Values shall not be interpolated. Use nearest safer value.
Reaching over the vertical detection zone of electro-sensitive protective
equipment
(Dimensions
in
mm)