5.2 Connection Example, for connection to safety relay
There are alternative possibilities for reset (see the following examples):
A
Automatic reset:
The safety relay is connected for automatic reset and terminal
1 (white cable) on the receiver is connected to 24VDC.
B
Manual Reset from relay:
The safety relay is connected for Manual reset and terminal 1
on the receiver (white cable) is connected to 24VDC
C
Manual Reset from Light Barrier:
The safety relay is connected for automatic reset and terminal
1 (white cable) on the receiver is connected to one side of a
push button (NC) and the other side is connected to 24VDC.
Switches 8 is set in “ON” position as default from factory connection examples (see 4.4). If example c is
required then Switch 8 must be set to “OFF”. If test/reset
is also connected it may be used for other
functions (see 2). The LMS indicator L1 signals opened barrier or safety relay.
NB!
If test/reset
is not connected, the white wire must be connected to 24VDC. If test/reset
and
are
pressed and are released at the same time, no reset occurs.
NB!
The connections in the drawing above which are marked with bold lines should only be made if the
muting function is to be used.
A B C D
*)
Test/
Reset
*)
A
*)
Test/
Reset
L1
*)
+
-
+
-
B C D
1
2
3
4
5
Brown
+24VDC
Blue
0V
Brown
+24VDC
Blue
0V
1
2
3
4
5
6
7
8
White
Test / Reset
Green
Yellow
Muting A
Muting B (NC for X-muting
OSSD 1 (RL 500mA max.)
OSSD 2 (RL 500mA max.)
Muting Lamp (220Ω / 3W)
Grey
Pink
Red
Screen
Ground
Screen
Ground
1
13
14
42
24
23
33
41
34
Y24
Y14
In
1&2
14
13
23
24
Type:RT6
A1
A2
Test/Auto
S24
ABB
S34
S13 S14
S23
S53
Y13
Reset
X1
X4
S13
Type:RT9
A1
A2
ABB
S14 S34
S44 S24
- +
Y14
Test/Auto
Reset
X1
X4
C
D
B
B
A
A
White
Black
Grey
2
2
T
ransmitter
Receiver
M12
Cable