![ABB Focus II FII-4-14 Series Original Instructions Manual Download Page 55](http://html.mh-extra.com/html/abb/focus-ii-fii-4-14-series/focus-ii-fii-4-14-series_original-instructions-manual_4042055.webp)
55
www.abb.com/lowvoltage
2TLC172015M0201, rev. D
22 Variant list and general schedule
Basic Connection
Resistor
220 Ohm 3W
A
R
M
Safety Light Curtain / Barrier
Cabinet
B
M12, 8pol. Female
M12, 8pol. Male or M12, 5pol. Male
Muting sensor A
Muting sensor B
4x M12,
5pol.Female
Safety Light Curtain / Barrier
Same as the
R connector
on FMC.
M12, 5pol.
Female
T
ina 10 A
is
the same
without the
connector
no.3 (R).
M12, 8pol. Female
M12, 5pol. Male
T
ina 10 C is the
same with
connector no.3
for power
supply to
transmitter
.
Alt. 6
Pre Reset.
Only with curtain in manual
reset. Not possible with
blanking curtains.
(* Max 3W total Resetlamp
on A
and R connector
.
1
4
5
+24V
Pre Reset
(Allways in
Pre Reset
mode.)
No Muting lamp (resistor).
1
2
3
4
+24V
Power "Of
f "
Reset lamp (*
T
est / Reset 1
1
3
24V supply
No Muting lamp (resistor).
1
4
+24V
Reset lamp (*
FOCUS
Connection unit FMC-1(2) / FMC-1(2) TINA
/ TINA
10 A,B,C
FMC-1(2) or
FMC-1(2) TINA
T
ina 10 A
/ B / C
FMC-1(2)
FMC-1(2) TINA
140mm
35mm
45mm
FMC-2
Has twin A/B
connectors and
total lengt of 183mm
FOCUS
In A
In B
Muting
OSSD 1
OSSD 2
Brown
White
Blue
Black
Grey
1
2
3
4
5
+24V
Not used
0V
Not used
Brown
White
Blue
Black
Grey
Brown
White
Blue
Black
Grey
+24V
Power "Of
f "
Reset lamp (<3W)
T
est / Reset 1
Muting lamp (3-5W)*
1
2
3
4
5
+24V
Not used
0V
Not used
Muting lamp (3-5W)*
Brown
White
Blue
Black
Grey
1
2
3
4
5
24V
supply to
transmitter
* Muting lamp total 3-5W
Led panel. "On"
In A
In B
Muting
OSSD1
OSSD2
Muting sensor A
activated
Muting sensor B activated
Led flashing
Led on
Safety output 1 "High"
Safety output 2 "High"
:
:
:
:
:
: Muting activated
: Muting lamp fault
Alt. 1 *
1
3
Supply to transmitter
Muting lamp
FMI-1
Alt. 2 *
Alt. 3 *
Sensor B1
Sensor B2
Sensor A2
Sensor A1
M12-3B
M12-3B
M12-3B
Receiver B
M12-3B
Receiver A
M12-3B
T
ransmitter A
T
ransmitter B
Alt. 4 *
Sensor A
+
Signal
from
cabinet
Sensor B
+
Signal
from
cabinet
Alt. 5 *
Sensor A
M12-3B
Supply to ?
M12-3B
Supply to ?
Sensor B
2 7 1
3 4 8 5
6
SCREEN BROWN BLUE WHITE GREEN YELLOW RE
D GREY
PINK
*1 Optional connection:
Either cabinet or FMC.
*2 OSSD output:
RL
max 500 mA.
*3 Mixable possibility:
Cabinet and / or FMC.
*1
Screen
24 VDC
0 VDC
Test/
Reset
Muting A
Muting B
LMS
OSSD 1
OSSD 2
*2
*2
1 2 3 4 5
SCREEN BROWN WHITE BLUE BLACK GREY
+24VDC 0V
Info
Muting
In B
In A
:
:
:
:
Muting sensor A
activated
Muting sensor B activated
Led flashing
Led on
Eden standard
Led panel. "On"
In A
In B
Muting
Info
: Muting activated
: Muting lamp fault
OSSD 2
OSSD 1
Muting
In B
In A
* These alternatives are mixable.
1
2
3
4
5
+24V
Not used
0V
Not used
A
& B connector:
+24V on pin 4 when muting is required.
*1
*3
Regarding all alternatives, on the connector "R":
In order to start up Focus light curtain/barrier you must
connect pin2 and 4, to pin1.
JS AP-1:
Adapter Plug.
1
2
3
4
5
T
ina 10 B
1
2
3
The muting lamp is optional and it is possible to put a resistor
(3W
, 220 Ohm) instead of a muting lamp.
Except on alt.6
.