12 Revision
Rev.
Description
Date Dept./Init.
1
Draft with focus on installing Bulk fed shelves. Pictures added
2
Reformatted sections. Corrected shelf depth in reference information
3
Removed
-
190V items including rear access converter shelf. Clarified sections to support
downward airflow as standard configuration for fan tray. Corrected drawings
June/2006
4
September Added transitional statements to improve flow. Added note on grounding practice
for best EMI performance to output connector pin out description. Added Ether net present
confirmation procedure
Sept/2006
5
References to multi
-
shelf configurations removed. Network inspection added
March/2007
6
Clarifications: Page 5, added
‘
converter shelf
’
after GR487. Page 9, Dissipation clarifications.
Page 10, Listed specific protector. Page 13, The return conductor
of the
-
48V shall be
terminated in the ground window, (held at frame ground potential). Page 13, The tele
communication line cable, carrying the +/
-
190V between the equipment and the primary
protectors ,shall be minimum 26 AWG, and rated minimum 200V. Page 13, Airflow must be
provided at a rate of 175 lfm
across the entire cross section of the shelf for operation in
environments up to 65 C, when measured at the inlet of the warmest converter shelf. Page 13,
For multi
-
shelf systems (up to 3), this equipment has been evaluated for continuous use in
ambient temperature from
-
40°C to 50°C when used with the QS982A converters. Page 28,
added: Otherwise all alarm cards should be left in
their factory default state of address 0,0.
Skip this step if no QS941 will be present in the system. Page 28, added text and changed
picture to show angle required to remove alarm card. Page 38, Measurement from the exterior
of the CPS3200U shelf to the cabinet or building ground bus should indicate a resistance of less
than 10 Ohms. Page 56, cleaned up some of the tense grammatical errors.
Changes: Pages 7 and 9: L1 and 2 currents. Page 13, changed J1 to TB1. Page 49,
Step
12“
J6
”
changed to
“
P6.
”
Page 65, changed outdoor applications to 2 shelf system configurations between fan shelves.
The operating temperature section now reads:
The CPS3200U is rated to work to 65 C in stacks of two shelves in outdoor cabinets without
baffles. Note: in outdoor cabinets where the air entering the second shelf may be heated above
65C inlet temperature, additional airflow beyond the 175 linear feet per minute is required.
These cases require an engineered solution.
In Central Office environments when baffles are required for safety reasons, a three shelf
system is rated to operate in 55C environments.
December/2007
7
Rebranding
January/2008
8
Rebranding, minor reformatting, and minor updates
July/2013
9
Corrected typos, restored Specification of Output Voltage, added weights for fan shelf and
baffle, updated figures showing converter shelf output side, updated figures showing baffle
and filter holder installation, and added section for Maintenance –
Filter Cleaning.
December/2013
10
Changed UL Class to A3.
July/2015
10.4
Updated as per template
10/06/2021
Summary of Contents for CPS3200U
Page 1: ...Page 1 2021 ABB All rights reserved PRODUCT MANUAL ...
Page 12: ...Page 12 2021 ABB All rights reserved This page intentionally left blank ...
Page 17: ...Page 17 2021 ABB All rights reserved Figure 2 Capacitance Safety Limits ...
Page 20: ...Page 20 2021 ABB All rights reserved This page intentionally left blank ...
Page 22: ...Page 22 2021 ABB All rights reserved This page intentionally left blank ...
Page 33: ...Page 33 2021 ABB All rights reserved Step Action 2 ...
Page 34: ...Page 34 2021 ABB All rights reserved Step Action Slide the filter in to the filter bracket 4 ...
Page 43: ...Page 43 2021 ABB All rights reserved Step Action 14 ...
Page 48: ...Page 48 2021 ABB All rights reserved ...
Page 51: ...Page 51 2021 ABB All rights reserved 10 Maintenance ...
Page 52: ...Page 52 2021 ABB All rights reserved This page intentionally left blank ...
Page 62: ...Page 62 2021 ABB All rights reserved This page intentionally left blank ...