Description of application and parameters
Application "RTC"
Product manual 2CKA001473B9679
│128
11.4.1 Setpoint adjustment - Setpoint adjustment via communication object
Options:
1-byte counter value
Absolute temperature value
Relative temperature value
The default is used to set the datapoint type with which a setpoint adjustment via the bus on the
device can be carried out. Available for selection are
– the 1-byte counter value in format DPT 6.010, which multiplied with the step size results in
the setpoint adjustment and
– the absolute (DPT 9.001) und
– relative (DPT 9.002) setpoint temperature.
11.4.2 Setpoint adjustment — Resetting of the manual adjustment for receipt of a basic
setpoint
Options:
No
Yes
Activating this parameter will cause the manual adjustment to be deleted and the new setpoint
value to be provided when a new value is received via the "Basic setpoint" object.
If the parameter is deactivated, the manual adjustment is added to the new base setpoint value.
Example: Previous base setpoint value of 21°C + manual adjustment of 1.5°C = 22.5°C. The
object receives a new basic setpoint of 18°C plus the previous manual adjustment of 1.5°C for a
total of 19.5°C.
11.4.3 Setpoint adjustment — Resetting the manual adjustment for change of operating mode
Options:
No
Yes
If the device switches to a new operating mode, the manual adjustment is deleted and the
parameterized setpoint temperature for the operating mode plus any change by the base
setpoint value object will be applied if this parameter is activated. Example: Comfort
temperature of 21°C plus manual adjustment of 1.5°C = 22.5°C. Change to Eco with
programmed temperature 17°C. The device regulates the temperature to 17°C, since the
manual adjustment is deleted.
If the parameter is deactivated, the manual setpoint adjustment will be added to the temperature
in the new operating mode. Example: Comfort temperature of 21°C plus manual adjustment of
1.5°C = 22.5°C. If the system switches to Eco with a parameterized temperature of 17°C, the