- 25 -
010CC4
4 - CDD display operations
M
ain menu - View
information
M
ain menu - Change
settings
MAIN menus
Statistics
of the system and each inverter
View Information
read only display
PN
of the CDD
SN
of the CDD
Firmware Rel.
> press ENTER to view
Application FW
Bootloader
FW
Wless
Firmware
RF
Firmware
Date
Time
Events, Alarms Present >
or NO alarms >
press ENTER to view log of alarm codes listed by date
and time, identified as CDD or MIC (inverter) serial number
Change Settings
modify CDD settings and acquire inverters
Change Language >
of the CDD, press ENTER and select language from the list
Set Date/Time >
of the CDD, press ENTER to change
Automatic: Yes
scroll to NO and press ENTER to change
DST: NO
scroll to YES to select daylight savings time if applicable
Enter date/time using UP/DOWN, press ENTER to accept change
Set Time Zone >
of the CDD, press ENTER to change
Set Time Zone
scroll UP/DOWN, press ENTER to select
GMT: +/- XX.XX
scroll UP/DOWN, press ENTER to select
Display Timeout >
press ENTER to change display timeout, 1 to 10 minutes or Off
Network, Change locked!
Wireless network is enabled by default and locked.
To change to Ethernet, wireless must first be disabled from BASIC menu
Network >
once wireless is disabled, press ENTER to change to Ethernet
Reset Ground Fault ?
Reset, Are you sure?
press ENTER to reset
Geo Position >
of the plant, press ENTER to change, use UP/DOWN to enter
latitude and longitude, press ENTER to accept change
Lat:/Long:
N/S xx.xx, E/W xx.xx
Country STD >
grid/country standard of the inverters, press ENTER and scroll
through the list of available grid standards, press ENTER to select
Remote update >
press Enter to check for available updates
No Update Avail., Check Now? >
Check for update, waiting . . . . .
Micro Manager
[Add] Inverters >
press ENTER to acquire inverters, GEO position and
timezone will display and always need to be entered for acquisition to start
Lat:/Long: >
use UP/DOWN to enter coordinates, ENTER to accept
Set Timezone >
use UP/DOWN to enter timezone, ENTER to accept
Scanning ….
for inverters will begin after GEO position and timezone
are entered (see acquisition process in part 5)
[ST] Inverters >
scroll DOWN list of inverters, press ENTER to view status
[Kll] Inverters >
to remove individual inverters from the CDD, press DOWN
to scroll inverters identified by number, MAC and serial number
[03]MAC: XXXXXXXX, SN:XXXXXX
press ENTER to select inverter
*** Kill >
press ENTER to remove inverter from CDD