Derating
Surrounding air temperature derating
In the temperature range +40…50 °C (+104…122 °F), the rated output current is derated
by 1 percentage point for every added 1 °C (1.8 °F). The output current can be calculated
by multiplying the current given in the rating table by the derating factor
(k)
:
T
1.00
0.90
+40 °C
+104 °F
+50 °C
+122 °F
k
0.80
Altitude derating
At altitudes 1000 … 2000 m (3281 … 6562 ft) above sea level, the output current derating
is 1 percentage point for every added 100 m (328 ft). For example, the derating factor for
1500 m (4921 ft) is 0.95. For altitudes above 2000 m (6562 ft), contact ABB.
If surrounding air temperature is below +40 °C, the derating can be reduced by 1.5
percentage points for every 1 °C reduction in temperature. A few altitude derating curves
are shown below.
1500 m
1000 m
+25 °C
+30 °C
+77 °F
+86 °F
+40 °C
+104 °F
+35 °C
+95 °F
+20 °C
+68 °F
3300 ft
4921 ft
2000 m
6562 ft
2500 m
8202 ft
3000 m
9842 ft
3500 m
11429 ft
4000 m
13123 ft
1.00
0.95
0.85
0.90
0.80
Derating factor 1.00
Derating factor 0.95
Derating factor 0.90
120 Technical data
Summary of Contents for ACS880-207
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 207 IGBT supply units Hardware manual ...
Page 2: ......
Page 4: ......
Page 53: ... 3 3 Electrical installation 53 11 ...
Page 54: ...3 54 Electrical installation ...
Page 81: ...4 5 6 7 8 6 10 10 Maintenance 81 ...
Page 94: ...5 6 10 3 4 7 9 8 94 Maintenance ...
Page 99: ... Maintenance 99 ...
Page 100: ... 100 Maintenance ...
Page 103: ...5 6 3 4 8 9 7 Maintenance 103 ...
Page 107: ...5 6 3 4 7 Maintenance 107 ...