34
ACS510 User’s Manual
Start-Up
Note!
Download Full Set writes all parameters to the drive, including motor
parameters. Only use this function to restore a drive, or to transfer parameters to
systems that are identical to the original system.
•
Download Application
– Copies a partial parameter set from the Control Panel
to a drive. The partial set does not include internal motor parameters, parameters
9905…9909, 1605, 1607, 5201, nor any Group 51 and 53 parameters. Use this
option to transfer parameters to systems that use similar configurations – the
drive and motor sizes do not need to be the same.
•
Download User Set 1
- Copies
USER
S
1 parameters (user sets are saved using
parameter 9902
APPLIC
MACRO
) from the Control Panel to the drive.
•
Download User Set 2
- Copies
USER
S
2 parameters from the Control Panel to the
drive.
The general procedure for parameter backup operations is:
1. Select PAR BACKUP in the Main Menu.
2. Press UP/DOWN to step to the desired option.
3. Press ENTER.
The parameter set is transferred as directed. During the transfer, the display shows
the transfer status as a percent of completion.
4. Press EXIT to step back to the Output mode.
Handling Inexact Downloads
In some situations, an exact copy of the download is not appropriate for the target
drive. Some examples:
• A download to an old drive specifies parameters/values that are not available on
the old drive.
• A download (from an old drive) to a new drive does not have definitions for the
new parameters – parameters that did not originally exist.
• A download can include an illegal value for the target drive, e.g. a backup from a
small drive can have a switching frequency of 12 kHz whereas a big drive can
only handle 8 kHz.
As a default, the control panel handles these situations by:
• Discarding parameters/values not available on
the target drive.
• Using parameter default values when the
download provides no values or invalid values.
• Providing a Differences List – A listing of the
type and number of items that the target cannot
accept exactly as specified.
You can either accept the default edits by pressing
READY, or view and edit each item as follows:
LOC
DIFFERENCES
----
VALUES UNDER MIN
VALUES OVER MAX
INVALID VALUES
EXTRA PARS
MISSING VALUES
READY
SEL
3
2
1
5
7
Supplied from China by: Guangzhou Tofee Electro Mechanical Equipment Co., Ltd
Email: [email protected]