Required tools and equipment
Note
Article number
Equipment
Content is defined in section
Standard toolkit for controller on
page 424
.
-
Standard toolkit
-
ESD protective wrist band
Required documents
Note
Article number
Document
3HAC065464-009
Circuit diagram - OmniCore C90XT
Removing the connected services gateway
Preparations
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
.
Open the door.
2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
3
xx1900001446
Continues on next page
Product manual - OmniCore C90XT
209
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.6 Replacing the connected services gateway
Continued
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 36: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 428: ...This page is intentionally left blank ...
Page 452: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......