Specifications
It is recommended to use multicore cable for the customer connection.
The following describes the cable requirements for the X106 connection in the
extension box.
Description
Component
Flexible oil resistant rubber
Cable type
4C x 0.5 mm
2
or AWG20
Cable area
Included parts
The following parts are included in the delivery when the extension box is selected.
Quantity
Order number
Part
1
3HAC074661-001
Connector for X106
Procedure
Use this procedure to stack an extension box to a basic box.
Info/illustration
Action
Place the controller in desired place.
1
Anchor bolts: M8 X 4
Fix the basic box to a concrete foundation
or steel platform with anchor bolts.
2
Tighten torque: 11.3 Nm-12.6 Nm
xx1900001450
Remove the four plastic screw.
3
Continues on next page
152
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.8.1 Installing the extension box
Continued
Summary of Contents for OmniCore C90XT
Page 1: ...ROBOTICS Product manual OmniCore C90XT ...
Page 36: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 428: ...This page is intentionally left blank ...
Page 452: ...This page is intentionally left blank ...
Page 456: ......
Page 457: ......