Mounting the OpenCom 150 Rack InfoCom System
75
Mounting the OpenCom 150 Rack
InfoCom System
The OpenCom 150 is also available as rack version for mounting in a standard 19" EIA
rackmount cabinet.
OpenCom 150 Rack Frame and Ports
Safety Precautions
The system needs to be mounted in earthed cabinets or cases. Lines and cables con-
nected to the communications system must only be laid inside buildings.
Use a shielded Ethernet cable (STP cable, Shielded Twisted Pair cable) to connect the
OpenCom 150 Rack to a Local Area Network (LAN).
The ambient temperature of the OpenCom 150 Rack infocom system should not
exceed 55°C. If the device is installed together with other active components, it may
be necessary to mount additional ventilation fans in the installation cabinet.
Patch cables have to be connected before connecting the system to the power
supply. Installation of the system, and in particular connection to the power supply
and protective earthing, should only be performed by skilled, qualified personnel. EN,
IEC regulations, along with other recognised technical rules regarding safety, must be
observed.
Please note:
Before opening the device, pull out the plug.