9. Appendix: test cable checking
Qulon-12ns is equipped with special cables with
clips utilizing four-wire (Kelvin) connection. At the negli-
gent treatment - for example, a detachment from the
device by pulling by a cable, they could be damaged. If
you have any doubts about cables, it is possible to
check them up, using a digital tester as follows.
A. Attach cable to Qulon-12ns.
B. Disconnect halves of both clamps from each
other (for example by installing a piece of cardboard or
plastic between halves).
C. Switch tester to resistance measurement
mode.
G. Connect tester to the halves of black
(negative) clamp - the tester should show resistance to
the order of 0.65 Mohm.
D. Connect tester to the halves of the red
(positive) clamp - the tester should show resistance at
least 2 MOhm or no contact.
E. Connect the halves of clamps (half crocodile
clips) to each other — remove insulators, placed before.
J. Connect tester between the black and red
clamps - tester should show resistance to the order of
0.25 Mohm.
-40-
10. Specifications
1. Working voltage range - 9 V to 15 V.
2. Recommended range of nominal capacity of
batteries to test – 0.9 to 350 ampere-hours.
3. Battery voltage range for battery capacity es-
timation – 12.6 to 13.9 В.
4. Battery testing time under basic filtering mode
– up to 1.5 s.
5. Powered – from the battery under test.
6. Test cable length – 0.6 m.
7. Weight – 0.4 kg.
8. Dimensions without cable - 135 x 70 x 23 mm.
9. Working temperature range - from 10 to 35
o
C.
10. Humidity up to 95 % without condensation.
11. Display type – graphical LCD.