Step
Parameters
Example 1
Example 2
Example 3
1
Ws 200kg 30.0kg 600kg
2 Ns
20,000 30,000 60,000
3 d’
2
3
6
4
d
2 (=0.02kg)
5 (=0.005kg)
10 (=0.1kg)
Ns x d
20,000 x 2
30,000 x 5
6,000 x 1
5
1/No (=d/Ns)
1/10,000
1/6,000
1/6,000
6. Calculate the voltage sensitivity “Es”.
Es = (As-Ao) x 5,000 x 1/No (µV) [5,000 means excitation voltage 5V]
Ao: Load cell output at zero point (mV/V)
As: Load cell output at full capacity (mV/V)
7. Check the voltage sensitivity “Es”.
Es
≥
0.5µV
Æ
Calculated “Ns x d” is fixed. In example 3 in the step 5, a 600kg x
0.1kg scale will be obtained.
Es<0.5µV
Æ
Change “d” for new resolution 1/No.
d=1
Æ
2
d=2
Æ
5
d=5
Æ
10
Æ
1 (dividing “Ns” by 10)
In example 1,
the new d=5: 1/No=d/Ns=5/20,000=1/4,000 (200kg x 0.05kg)
In example 2,
the new d=1 and Ns=3,000: 1/No=d/Ns=1/3,000 (30kg x
0.01kg)
Using the new 1/No, go to step 6 and repeat it until Es
≥
0.5µV in step
7.
Remote Scale kg/lb relationship
USA Version ONLY
When the capacity was set by “kg”:
Let capacity x minimum division = Ws x W
d
(kg)
When:
d = 1, then W
d
(lb) = W
d
(kg) x 2
d = 2, then W
d
(lb) = W
d
(kg) x 5/2
d = 5, then W
d
(lb) = W
d
(kg) x 2
And:
Ws (lb) = W
d
(kg) x No
Example: 15kg x 0.002kg, No = 15kg/0.002kg =7,500
W
d
(lb) = 0.002 x 5/2 = 0.005 (lb)
Ws (lb) = 0.005 (lb) x 7,500 = 37.5 (lb)
When the capacity was set by “lb”:
Let capacity x minimum division = Ws x W
d
(lb)
When:
d = 1, then W
d
(kg) = W
d
(lb) x 1/2
d = 2, then W
d
(kg) = W
d
(lb) x 1/2
d = 5, then W
d
(kg) = W
d
(lb) x 2/5
And:
Ws (kg) = W
d
(lb) x No
Example: 30lb x 0.005lb, No = 30lb/0.005lb =6,000
71