2. Fully loosen the lock screw and remove the battery.
If you want to recharge the battery while it is still in the scale, you may do so. In that
case, disregard step 2 – but do not turn the battery switch on. If you wish to use the
scale, connect another AC adapter.
3. Connect the AC adapter to the battery pack.
The battery pack will take about 15 hours to fully charge.
Charge the battery pack at a temperature between 0°C (32°F) and 40°C (104°F).
Do not charge too long as overcharging will reduce the life of batteries.
Be sure to charge the battery pack when using for the first time or if it was not used
for long time (more than one month). Two or three times of recharging may be
needed to reach full charge.
Be sure to use the AC adapter that is provided with the scale.
Battery
switch
AC Adapter
to battery pack
AC Adapter
to scale
Charge
Scale operation
ON or OFF
Connected
Connected
Yes
Operational
ON or OFF
Not connected
Connected
No
Operational
OFF
Connected
Not connected
Yes
Not operational
ON
Connected
Not connected
No
Not recommended (See note)
Note The scale will be operational. After connecting the AC adapter to the battery
pack, you may have to turn the battery switch OFF once and turn it ON to
operate the scale.
66
Summary of Contents for FC-5000Si
Page 60: ...Comparator upper limit 12345 Codabar NW 7 A17 000012345A 58...
Page 79: ...World map 77...
Page 82: ...MEMO 80...
Page 83: ...MEMO 81...
Page 84: ...key Space code Standby indicator 82...
Page 85: ......
Page 86: ......