Technical characteristics

 

The installation and use conditions are:

• 

AAF pre-filter Technical Data Sheet

• 

AAF HEPA filter Technical Data Sheet

• 

AAF Filter change out recommendations

• 

AAF filter storage recommendations

Technical details of fan and UV-C stage are relevant only to service / repair personnel.
For the most current versions visit us at www.aafeurope.com 

Accompanying guidelines and documents

Parameter

Unit

AstroPure - 2000

Nominal flow rate

m

3

/h

2000

Dimensions (WxLxH)

mm

770x720x1628*

Device weight

kg

150*

Min. ambient temperature

°C

0

Max. ambient temperature

°C

40

Allowed rel. humidity level

%

0-90

* depending on execution

Connection details and power consumption

Connection details

1PH 230V 50 / 60Hz

Fan

kW

0,5

UV-C stage

W

25

Sound pressure level (SPL) at a distance of 1 m

Db(A)

24-55

SFP

kW/m³/s

0,513 (Fan type "E")
0,452 (Fan type "Z")

IP-class

IP20

Maximum recommended pressure drop:

Pre filter

RedPleat

Pa

250

RedPleat VF

Pa

250

HEPA filter:

AstroCel III

Pa

450

MEGACel I

Pa

450

Table 1 : Technical parameter of AstroPure 2000 Air Cleaner

Components

Image 2  AstroPure with Potentiometer Control

Image 3  AstroPure with LCD / PLC Control

5

8

1

10

11

12

13

14

16

4

7

³

6

2

9

5

8

1

1

6

4

³

7

6

9

2

Summary of Contents for AstroPure 2000

Page 1: ...AstroPure 2000 Air Cleaner IOM AstroPure Installation and Operation Manual...

Page 2: ...transport and assembly 13 Commissioning Operation Cleaning and Disposal 19 Emergency 20 Drawings and diagrams 21 Spare parts 21 Certificates and Protocols 22 Appendix Potentiometer Control Manufacture...

Page 3: ...be trained and instructed for example according to VDI 6022 4 The AstroPure air purifier is shipped with an installation operation and maintenance manual AAF HEPA filter test report For maintenance i...

Page 4: ...switch in OFF Set the speed controller to the OFF position Plug in the power plug ON OFF switch ON Check serial number for fan type on the Type Plate on the back of the uni Serial No E11 2020 12345 E...

Page 5: ...teristics example below Image 1 AstroPure type label 3 Quick Start Guide LCD PLC Control Quick start guide Observe the safety instructions for safe operation Ensure a safe stand on smooth level stable...

Page 6: ...Device weight kg 150 Min ambient temperature C 0 Max ambient temperature C 40 Allowed rel humidity level 0 90 depending on execution Connection details and power consumption Connection details 1PH 23...

Page 7: ...ackaging Storage temperature range 30 C to 40 C Air humidity rH 90 no condensable humidity Unpacking Remove the securing straps stretch wrap and card board packing material from the AstroPure 2000 Air...

Page 8: ...vice is properly closed Make sure that the air inlet and outlet openings are freely accessible and not obstructed or occupied Fix the locking devices of the castors General In case of any abnormal noi...

Page 9: ...be set here Press the plus and minus button The respective speed increment is set in the configuration menu Method 2 Press an area on the flow rate bar With this option the speed of the fan is set to...

Page 10: ...ied below or earlier if necessar 18 Parameter Symbol Unit Example 1 Example 2 Example 3 Example 4 Length L m 10 10 10 10 Width W m 10 10 10 10 Height H m 2 2 5 2 5 2 5 Volume V m3 200 250 250 250 Air...

Page 11: ...enwaldstrasse 4 D 64646 Heppenheim Germany Telefon 49 0 6252 69977 0 Email Sales DACH aafeurope com A risk assessment and compliance evaluation procedure has bend conducted referenced on the following...

Page 12: ...LLED PRODUCT OWNER FM AAF DRAWING NO mm SHEET UL DO NOT SCALE DRAWING REF Material Finishing MATER Roughnes 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D E E F F AP2000 LCD Guillaume Fogeron 19 03 2...

Page 13: ...10 663 51 09 E mail greece aafeurope com Italy AAF S r l Via Friuli 28 30 21047 Saronno VA Phone 39 02 9624096 Fax 39 02 9606409 E mail sales italy aafeurope com Dinair Norway Dinair AS Prof Birkeland...

Reviews: