6
7
1. Safety
Operation may only be carried out after a instruction and training.
Maintenance and repair may only be carried out by qualified personnel.
Observe the principles for the safe operation of electrical devices.
For maintenance and repair work, the accompanying documents for the supplier
components must be observed.
Hazard potential emanating from the AstroPure Air Cleaner.
Electric shock:
Electrical supply line can possibly be defective.
Under no circumstances use devices with a damaged electrical connection cable.
• Check the power cords before use.
• Damaged cables must be replaced immediately.
• Electric cables must never be exposed to water, heat or sharp objects.
• Do not move the device by pulling the power cord.
• Avoid running equipment and vehicles over power lines, or provide adequate protection
for them.
• The device should be in the off mode to connect or disconnect the main power supply.
• Internal cabling (fan, control panel, UV-C stage) can be defective.
• Do not continue to operate devices with an internal error and, if possible, disconnect
them from the power supply.
• Carry out maintenance and repair work only when the power supply is disconnected and
the AstroPure air purifier is switched off.
Crushing Hazard:
Due to its own weight, there is a risk of crushing when transporting and moving the
AstroPure air purifier.
This can result in bruising of the extremities.
The AstroPure air purifier must be moved with an appropriate method to avoid accidental
injury or damage of any kind.
Preferred method is to use approved lifting gear and secured against unintentional lowering
of the load:
1. protect the forklift forks before lifting
2. lift up slighty the AstroPure unit using the forklift and remove it from the wooden pallet
3. put down the AstroPure unit using the forklift
2. Quick Start Guide (Potentiometer Control)
Quick start guide
•
Observe the safety instructions for safe operation
•
Ensure a safe stand on smooth, level, stable ground/floor
•
Lock the castor wheels
•
ON / OFF switch in OFF
•
Set the speed controller to the “OFF” position
•
Plug in the power plug
•
ON / OFF switch ON
•
Check serial number for fan type on the Type Plate on the back of the uni
Serial No. : E11-2020-12345 => “E”-type
Serial No. : Z11-2020-12345 => “Z”-type
•
Rotate speed setting to desired air volume flow according to the table below
DANGER: ELECTRIC
SHOCK
DANGER: CRUSHING
HAZARD
There is a risk of crushing when
opening the maintenance door.
This can result in bruising of the
extremities. Have device
maintenance and repair carried
out by qualified personnel only.
DANGER: CRUSHING
HAZARD
The device can tip over if lifted
(excessively). This can result in
bruising of the extremities.
Do not tilt the device.Set up the
device outside the area of
movement of people.
DANGER: CRUSHING
HAZARD
Optional: The AstroPure air
purifier is equipped with an
additional UV-C stage. UV-C
radiation bears the risk to cause
severe damages to the eye and
skin. The UV-C stage is not
accessible during normal
operation.
DANGER: ROTATING
DEVICE
Fast rotating parts of the fan
The high-speed impeller of the
fan can injure body parts on
contact. Have device aintenance
and repair carried out by qualified
personnel only.
Speed Control
Set Point
Fan Type
E
Fan Type
Z
0
0
0
1
0
0
2
300
50
3
600
250
4
950
500
5
1250
750
6
1600
1050
7
1900
1350
8
2200
1650
9
2400
2000
10
2400
2300
Yellow warning lights light up:
Filters must be changed by qualified personnel
- Note the date of first use
- Note down the operating time
- Observe and document change intervals for filters
Have the filter change and maintenance carried out by qualified personnel only
In the event of danger or malfunction:
Pull out the mains plug and have the device serviced by qualified personnel
Observe the protective
instructions on the device.
Secure the open maintenance
door against unintentional
closing.
EAR PROTECTIONS
Have device maintenance and
repair carried out by qualified
personnel only. Sufficient hearing
protection must be worn during
maintenance and repair work
when the fan is running.
DANGER: NOISE
The unencapsulated fan can
generate sound emissions>
70dB (A) (with the aintenance
door open). Damage or loss of
hearing can result.
Step 1
Step 2
Step 3