Command Set
Set Flow Control
The
set flow control
command provides control over the flow control setting of the
local EmbeddedBlue module.
Syntax
set
flow none | hardware [*] <CR>
Parameters
none
Configures the module for no flow control and both the RTS
and CTS lines are configured as high Z inputs. This allows
an application to use these lines a normal I/O.
hardware
Configures the module for hardware flow control. The RTS
line is used for receive flow control and the CTS line is used
for transmit flow control.
*
An optional parameter used to persist the new setting when
the module is powered down.
Example
>set flow none<CR>
ACK<CR>
>
EmbeddedBlue 505 User Manual
▪
Page 33