www.a-ts.cn A-TS Technology RT10
51
PA27
Internal speed
command 1
-9000 -
9000
0
rpm
S
PA28
Arrival speed
0 - 3000
500
rpm
P, S
PA29
Load rotation inertia
ratio
0 - 8000
200
%
P, S
PA30
★
Motor torque overload
alarm value
10 - 300
160
%
ALL
PA31
★
Motor torque overload
alarm detection time
0 - 12000
3000
ms
ALL
PA32
Control mode switch
allowed
0 - 1
0
ALL
PA33
Rigidity level
0 - 31
0
ALL
PA34
Internal CCW torque
limit
0 - 300
300*
%
ALL
PA35
Internal CW torque
limit
-300 - 0
-300*
%
ALL
PA36
Speed command filter
time constant
0 - 10.0
0.2
ms
ALL
PA37
Torque feed forward
filter time constant
0 - 10.0
0.5
ms
ALL
PA38
DP menu dynamic
display items
0 - 300
ALL
PA39
Serial communication
rate
0 - 15
0
T
PA40
Acceleration time
constant
0 - 10000
20
ms,0 to max
speed time
S