Indication
Cause
Measure
Water leakage
There is a leakage from a threaded
water connection.
Tighten the threaded connection.
There is a condensate leakage
Make sure that the condensation water
discharge is working properly.
If necessary, correct the water discharge.
There is a leakage from another nearby
water heater or pipe segment.
Trace the leakage.
There is a leakage from the water heater
tank.
Contact the supplier of your water heater.
Explosive ignition
The gas supply pressure is incorrect.
Check the gas supply pressure, refer to Gas
supply pressure.
The CO
2
value is incorrect.
Check the CO
2
(see 8.9.4).
The burner is contaminated.
Clean the burner, refer to Gas-side
maintenance (see 11.4).
There is an air leakage between the
venturi and the air connector.
Make sure that:
-
the air connector is not damaged.
If necessary, replace the air connector.
-
the air connector is correctly
connected to the venturi.
If necessary, tighten the clamp.
The air inlet filter is contaminated.
Clean the air inlet filter (see 11.4.3).
Insufficient or no
hot water
The water heater is off.
Turn on the water heater (see 4.1).
There is no supply voltage.
Make sure that:
the control switch is set to I.
the isolator is in ON position.
there is power on the isolator.
there is power to the electrical connector
block.
The measured voltage must be
230 V
AC
(-15%, +10%).
The hot water supply is used up.
Reduce the hot water consumption. Wait
until the water heater heats up.
The controller is in the OFF mode.
Set the controller in the ON mode.
The setpoint is set too low.
Set the setpoint to a higher value.
The external ON mode switch is not
enabled.
Set the "External use Enabled" to Yes. (see
10.5.1)
74
Installation, Maintenance and Service part
Summary of Contents for TWI 35-200
Page 6: ...6...
Page 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Page 26: ...26 User part...
Page 34: ...34 Installation Maintenance and Service part...
Page 54: ...54 Installation Maintenance and Service part...
Page 56: ...56 Installation Maintenance and Service part...
Page 66: ...66 Installation Maintenance and Service part...
Page 72: ...72 Installation Maintenance and Service part...
Page 80: ...80 Installation Maintenance and Service part...
Page 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...