Button
Function
[ ]
Scroll up / Raise
[ ]
Scroll down / Lower
3.2
Status of the water heater
During operation, the display shows the status of the water heater.
Fig. Display
MENU
Tank Temperature
Operating Setpoint
Status: Stand-by
60°C
60°C
The following status texts can appear on the display:
Status text
Explanation
Stand-by
The water heater is not heating because there is
no heat demand.
OFF
Stand-by (water temperature drops). The control
switch is set to 0.
Pre-Purge
The ventilator ventilates the combustion chamber.
Spark plug activated
The spark plug starts to spark.
Gas valve on
The gas valve is open.
Flame verification
A flame is detected.
Inter-Purge
After ignition has failed and before a new attempt,
the combustion chamber is ventilated.
Heating
The water heater is heating up water.
Post-Purge
The combustion chamber is ventilated after a
heating cycle.
Error
The controller has detected an error.
Error - Water heating
disabled
The heating cycle is stopped because the controller
has detected an error
Error - Post-Purge
An error is detected and the combustion chamber
is ventilated.
0313279_TWISTER II_UKUK_
V1.1, 18-02-2019
21
Summary of Contents for TWI 35-200
Page 6: ...6...
Page 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Page 26: ...26 User part...
Page 34: ...34 Installation Maintenance and Service part...
Page 54: ...54 Installation Maintenance and Service part...
Page 56: ...56 Installation Maintenance and Service part...
Page 66: ...66 Installation Maintenance and Service part...
Page 72: ...72 Installation Maintenance and Service part...
Page 80: ...80 Installation Maintenance and Service part...
Page 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...