8.9.2
Air pressure differential
Check the air pressure differential across the air pressure switch:
1.
Disconnect hose H of the air proving switch and connect this side of the hose to the
+ of the pressure gauge.
2.
Disconnect hose L of the air pressure switch and connect this side of the hose to the
- of the pressure gauge.
3.
Turn on the water heater (see 4.1).
4.
Read the pressure value from the pressure gauge while the water heater is pre-
purging.
5.
Compare the measured value to the value from the table (see 13.1).
Note
When the air pressure differential is not correct, refer to Displayed errors (see 12.1.2),
error LDS with code XAC–XXXX.
6.
Set the control switch on the front of the water heater to 0 to turn off the water
heater.
7.
Disconnect the pressure gauge.
8.
Reconnect the hoses of the air proving switch and the gas valve.
Fig. Air pressure differential
H
L
8.9.3
Gas supply pressure
Check the gas supply pressure:
1.
Loosen the sealing screw (2) of the test nipple by a few turns.
Note
Do not completely loosen the sealing screw, it can be difficult to retighten it.
2.
Open the gas supply to vent the gas pipes through the test nipple.
3.
Connect a pressure gauge to the test nipple as soon as you smell gas.
4.
Turn on the water heater (see 4.1).
5.
If necessary, create a heat demand:
-
Use a hot water draw-off point to tap water, or
-
Raise the setpoint of the water temperature, refer to Set the water
temperature.
6.
Wait about 1 minute.
n
n
50
Installation, Maintenance and Service part
Summary of Contents for TWI 35-200
Page 6: ...6...
Page 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Page 26: ...26 User part...
Page 34: ...34 Installation Maintenance and Service part...
Page 54: ...54 Installation Maintenance and Service part...
Page 56: ...56 Installation Maintenance and Service part...
Page 66: ...66 Installation Maintenance and Service part...
Page 72: ...72 Installation Maintenance and Service part...
Page 80: ...80 Installation Maintenance and Service part...
Page 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...