Refer to C13/C33 parallel systems (see 8.7.2) for the A.O. Smith part numbers. The same
parts can be used for the C43, C53 and C63 parallel systems.
Use the "adapter box concentric to parallel - water heater side" (part number 0312209) for
C63 parallel systems.
8.8
Electrical connections
Warning
Leave the water heater electrically isolated until you are ready to commission it.
8.8.1
Preparation
Remove the cover of the water heater to make the electrical section and the terminal block
visible:
1.
Use a screw driver to remove the screws at the right side cover (1).
2.
Hinge the cover towards the front.
3.
Take the cover from the water heater.
Fig. Remove the covers
The mains power and optional electrical connections have to be connected to the terminal
block of the controller, refer to Structure of the water heater (see 7.1).
Fig. Terminal block
2
3
1
1.
Grommet
2.
Electrical connection
3.
Connection external ON
mode switch
w
48
Installation, Maintenance and Service part
Summary of Contents for TWI 35-200
Page 6: ...6...
Page 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Page 26: ...26 User part...
Page 34: ...34 Installation Maintenance and Service part...
Page 54: ...54 Installation Maintenance and Service part...
Page 56: ...56 Installation Maintenance and Service part...
Page 66: ...66 Installation Maintenance and Service part...
Page 72: ...72 Installation Maintenance and Service part...
Page 80: ...80 Installation Maintenance and Service part...
Page 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...