background image

ORIGINAL INSTRUCTION

INSTRUCTIONS MANUAL

Gas heater 15KW

BUILDER SAS
ZI – 32, rue Aristide Bergès, 31270 Cugnaux, France

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE ASFE AND

EFFECTIVE USE OF THIS PRODUCT

Model: FCD15KW-1

Summary of Contents for FCD15KW-1

Page 1: ...ION INSTRUCTIONS MANUAL Gas heater 15KW BUILDER SAS ZI 32 rue Aristide Bergès 31270 Cugnaux France IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE ASFE AND EFFECTIVE USE OF THIS PRODUCT Model FCD15KW 1 ...

Page 2: ... 2 Additional safety instructions 3 Getting to know your gas heaters 4 Fuel gases Ventilation 5 Operation and use 6 7 Maintenance and storage 7 Troubleshooting Disposal 8 SPECIFICATION Manufacturer policy of continuous improvement determines the right to change specification without notice Stock No FCD15KW 1 Rated voltage 220 240V 50Hz Motor rated input 28W Protection class IP20 Heating output 15K...

Page 3: ...njuries c Prevent unintentional starting Ensure the switch is in the off position before connecting to power source d Remove any adjusting key or wrench before turning the heater on A wrench or a key left attached to a rotating part of the heater may result in personal injury e Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose cl...

Page 4: ...e suitable for minimum heating space General according to power 10W cbm calculation For example 20KW minimum space capacity of 2000 cubic meters WARNING Fire burn inhalation and explosion hazard Keep solid combustibles such as building materials paper or cardboard a safe distance away from the heater Never use the heater in spaces which do or may contain volatile or airborne combustibles or produc...

Page 5: ... condition and that there are no visible damaged parts If in doubt do not use the product and contact the dealer from whom it was purchased Do not use until unit has been repaired The packing materials plastic bags polystyrene etc Myst be disposed of in an appropriate refuse collection container These materials must not be left within the reach of children as they are potential sources of danger ...

Page 6: ...opane and butane are heavier than air If there is a leakage it sinks to the lowest possible level collecting there with the surrounding air forming a potentially explosive mixture It is prohibited to use these gas heaters in high rise flats bedrooms bathrooms basements or below ground level VENTILATION WARNING Be sure that the heater is only ever used with correct ventilation Make sure that no obj...

Page 7: ...plosion Screw fasten the gas hose with regulator to the cylinder valve Ensure the connection is tight NOTE The gas connection to the heater has a left hand thread WARNING Do not adjust regulator Screw fasten the gas hose to the heater ensuring that the rubber hose is not twisted or kinked Ensure the connection is gas tight START Fig 5 Plug in the mains lead to a wall socket Press the ON OFF switch...

Page 8: ...ade as necessary IMPORTANT The in use period between every repeat operation should not be less than 3 minutes MAINTENANCE AND STORAGE Regular inspection and cleaning reduces the necessity for maintenance operations and will keep your heaters in good working condition The Motor must be correctly ventilated during the heater is operating For this reason avoid blocking the air inlets If the replaceme...

Page 9: ...ugh 2 Safety thermostat activated 3 Restricted air flow 1 Repeat ignition process and keep safety gas valve depressed for a minimum of 30 seconds then release slowly 2 Allow the heater to cool down for at least 10 minutes Check thermostat and then attempt re light sequence correctly 3 Check heater inlet and outlet remove any obstructions TROUBLESHOOTING DISPOSAL At the end of the machines working ...

Page 10: ...e provisions of the following European directives Directive EU 2016 426 LVD Directive 2014 35 EU EMC Directive 2014 30 EU ROHS Directive 2011 65 EU 2015 863 Also conforms to the following standards EN 1596 1998 A1 2004 Cugnaux 27 06 2020 Philippe MARIE PDG Responsible for the technical file Mr Olivier Patriarca Gas heater 15KW Model FCD15KW 1 S N 20200821150 20200821299 ...

Page 11: ... the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the information contained therein but a modification will be undertaken without notice if it is recognized as an improvement of the preceding characteristic READ THE MANUAL CAREFULLY BEFORE USING THE MACHINE When o...

Page 12: ...e before dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is completed on the SWAP Europe site For machines with engine failure from manufacturers BRIGGS STRATTON HONDA and RATO please refer to the following instructions Repairs will be done by approved engine ...

Page 13: ...necessary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair station The use of a product which would show a defect or a breakage which was not the subject of an immediate report and or repair with the services of SWAP Europe Deterioration linked to transport ...