Technical details
Description
Unit
TWI 35-200
TWI 45-200
General
Capacity
l
182
182
Empty Weight
kg
79
79
Maximum floor load
kg
261
261
Maximum operating pressure
kPa (bar)
550 (5.5)
550 (5.5)
Control thermostat -
adjustment range
°C
40-85
40-85
Control thermostat -
default
value
°C
65
65
Hysteresis upwards -
adjustment range
°C
0
0
Hysteresis upwards -
default
value
°C
0
0
Hysteresis downwards -
adjustment range
°C
2-10
2-10
Hysteresis downwards -
default value
°C
5
5
Number of (electrical) anodes -
0
0
Fan speed at ignition
rpm
5000
5000
Fan operating speed
rpm
7200
9200
Minimum measured air
pressure differential across
the pressure switch
Pa
> 420
> 420
Setpoint pressure switch
Pa
370
370
Heating time ΔT = 45°C
min.
17
13
Electrical
Electrical power consumption
W
160
230
0313279_TWISTER II_UKUK_
V1.1, 18-02-2019
81
Summary of Contents for TWI 35-200
Page 6: ...6...
Page 13: ...User part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 25: ...Installation Maintenance and Service part 0313279_TWISTER II_UKUK_V1 1 18 02 2019 25...
Page 26: ...26 User part...
Page 34: ...34 Installation Maintenance and Service part...
Page 54: ...54 Installation Maintenance and Service part...
Page 56: ...56 Installation Maintenance and Service part...
Page 66: ...66 Installation Maintenance and Service part...
Page 72: ...72 Installation Maintenance and Service part...
Page 80: ...80 Installation Maintenance and Service part...
Page 87: ...13 6 Declaration of conformity 0313279_TWISTER II_UKUK_V1 1 18 02 2019 87...